Dear Editor,

We read with interest the comment made by Dr. Peet [1] on our article “Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight” [2]. The author states that our results do not agree with theirs and others’ experience. In their experience, they did not find a reduced among-patient variability of the liver contrast enhancement (CE) on abdominal CT when using the lean body weight (LBW) instead of the total body weight (TBW) to calculate the contrast agent volume to be injected. While we understand the author’s argument, it is important to highlight that, in our article, we do not make that direct conclusion. We only found that the variability of the liver CE decreased from underweight to obese patients; however, we did not dose the contrast agent according to the LBW. Our main finding was that, in the daily practice of our institution, radiologists do apply a subjective non-standard compensation for obese patients, by administering a contrast agent volume that is lower than theoretically calculated according to the TBW. In the Discussion, we merely speculate on the fact that radiologists make an adjustment of the contrast agent dose according to a putative LBW.

Furthermore, the hypothesis of a reduction of the liver CE variability associated with the use of LBW instead of TBW has been the rationale of a randomized controlled trial we have conducted at our institution. From preliminary analysis, data seem in line with previous studies, showing no reduction of liver CE variability when using LBW. However, we did not deem it necessary to normalize the liver CE to iodine volume, as we compare the liver CE in two randomized groups that were administered the same contrast agent and concentration.

Importantly, in our opinion, when describing parenchymal enhancement, especially of the liver, a multiparametric approach is most likely necessary. It should be a non-linear function of several variables, some of which have probably not been specifically investigated yet. Thus, a single-parameter approach, though easy to use, is inadequate. Studies are needed to develop an accurate model for prediction of the liver CE and for personalizing the contrast agent dose to be administered.

We also understand the author’s concern about the lack of a formal image quality evaluation. We are convinced that a binary diagnostic/non-diagnostic assessment could be considered too simplistic, even though directly derived from the clinical practice in a retrospective design.

References

  1. Peet K (2020) Letter to the Editor - Re: Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight. Eur Radiol Exp https://doi.org/10.1186/s41747-020-00178-x

  2. Zanardo M, Doniselli FM, Esseridou A et al (2018) Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight. Eur Radiol Exp 2(1):41. https://doi.org/10.1186/s41747-018-0074-1

Download references

Funding

None

Author information

Authors and Affiliations

Authors

Contributions

MZ and GdL wrote this reply letter. The authors read and approved the final manuscript.

Corresponding author

Correspondence to Moreno Zanardo.

Ethics declarations

Ethics approval and consent to participate

Not applicable

Consent for publication

Not applicable

Competing interests

None

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zanardo, M., Di Leo, G. Reply to Letter to Editor: Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight. Eur Radiol Exp 4, 46 (2020). https://doi.org/10.1186/s41747-020-00179-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s41747-020-00179-w

Keywords