Response to: Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight

A Letter to the Editor to this article was published on 22 September 2020

I read the study by Zanardo et al. entitled “Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight” [1] with interest. This study found that radiologist-derived, non-standard adjustments in contrast dosing were effective in reducing total contrast media dosing without significant impact on image quality. Our group shares a similar interest in optimizing contrast media dose, but found dissimilar results; patients randomized to a lean body weight dosing regimen in our study did not have significant reduction in the variability of mean hepatic enhancement [2]. We have several comments.

First, I agree that lean body weight may more accurately predict the volume of contrast needed; lean tissue can be expected to have a different metabolic activity and contrast uptake than adipose tissue. Previous studies in Japanese populations have demonstrated differences in enhancement per gram of contrast enhancement program of iodine [2,3,4,5,6,7] but conclusions that lean body weight dosing strategies will reduce interpatient variability have relied on inferences. A recent randomized controlled trial by our group in a North American population did not demonstrate any significant differences in contrast enhancement per gram of iodine or the variance of the mean hepatic enhancement between lean body weight dosed and total body weight dosed cohorts [2]. This is interesting, given our study design was similar on many points including the following: similar putative physiologic basis, similar measurement of lean body weight by bioelectrical impedance, as well as similar scanning protocols. Importantly, we normalized mean hepatic enhancement to iodine dose (MHE/I) in order to compare the yield of contrast media on hepatic visceral enhancement; this calculation would be very useful and interesting in the study by Zanardo et al. [1].

Second, the dosing strategy used in the study was entirely total-body-weight-based for most patients, with an ad hoc adjustment for doses that were subjectively considered too high. While this strategy would have the effect of decreasing the total contrast dose for patients at the high end of the range, it does not explicitly differentiate between high lean body weight and high total body weight patients, and does not account for lean patients at all.

Third, the authors state that “all CT examinations were judged as diagnostic and no patients received a repeat examination,” and have offered a proposed dose of 0.63 g of iodine per kilogram of lean body weight as a reasonable dosing standard. However, in this study, there is no formal evaluation of image quality or grading. In my experience, radiologists do not judge imaging quality enough, and the absence of such commentary within the radiologist reports does not imply diagnostic quality. In practice, the imaging quality of abdominal CT is better thought of on a sliding scale of varying quality, rather than a binary diagnostic/nondiagnostic paradigm.

References

  1. Zanardo M, Doniselli FM, Esseridou A et al (2018) Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight. Eur Radiol Exp:2

  2. Costa AF, Peet K, Abdolell M (2019) Dosing iodinated contrast media according to lean versus total body weight at abdominal CT: a stratified randomized controlled trial. Acad Radiol 1076-6332(19)30363-0

  3. Kondo H, Kanematsu M, Goshima S et al (2010) Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume. Radiology 254:163–169

    Article  Google Scholar 

  4. Kondo H, Kanematsu M, Goshima S et al (2013) Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight? Eur Radiol 23:1855–1861

    Article  Google Scholar 

  5. Kondo H, Kanematsu M, Goshima S et al (2010) Aortic and hepatic enhancement at multidetector CT: evaluation of optimal iodine dose determined by lean body weight. Eur J Radiol 80:e273–e277

    Article  Google Scholar 

  6. Ho LM, Nelson RC, Delong DM (2007) Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi–detector row CT? Radiology 243:431–437

    Article  Google Scholar 

  7. Awai K, Kanematsu M, Kim T et al (2016) The optimal body size index with which to determine iodine dose for hepatic dynamic CT: a prospective multicenter study. Radiology 278:773–781

    Article  Google Scholar 

Download references

Acknowledgements

Dr Andreu F. Costa

Funding

None.

Author information

Authors and Affiliations

Authors

Contributions

Solely written by Dr. Kris A. Peet. The author read and approved the final manuscript.

Corresponding author

Correspondence to Kris A. Peet.

Ethics declarations

Ethics approval and consent to participate

Not applicable

Consent for publication

Not applicable

Competing interests

None.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Peet, K.A. Response to: Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight. Eur Radiol Exp 4, 56 (2020). https://doi.org/10.1186/s41747-020-00178-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s41747-020-00178-x

Keywords