Skip to main content

Table 2 Median and interquartile range (IQR) for conventional images, 130-keV monoE, conventional images with O-MAR, 130-keV monoE with O-MAR, and DL-MAR images

From: Image quality and metal artifact reduction in total hip arthroplasty CT: deep learning-based algorithm versus virtual monoenergetic imaging and orthopedic metal artifact reduction

 

Conventional (median, IQR)

130 keV

Conventional + O-MAR

130 keV + O-MAR

DL-MAR

Image quality

1 (1–2)

1 (1–2)

2 (2–3)a

2 (2–3)a

3 (3–4)b

Diagnostic confidence

 Bone

1 (1–1)

1 (1–2)

2 (2–3)a

2 (2–3)a

4 (3–4)b

 Pelvic organs

1 (1–2)

1 (1–1)

2 (2–3)a

2 (1–3)a

4 (2–4)a

 Soft tissue adjacent to the prosthesis

1 (1–2)

1 (1–2)

2 (2–3)a

2 (2–3)a

3 (3–4)b

Metal artifacts

1 (1–1)

1 (1–1)

2 (2–3)a

2 (2–3)a

3 (3–4)b

  1. IQR Interquartile range, O-MAR Orthopedic metal artifact reduction, DL-MAR Deep learning-based metal artifact reduction
  2. aSignificant reduction in comparison to conventional images and 130-keV monoE
  3. bSignificant reduction in comparison to conventional images, 130-keV monoE, conventional images with O-MAR, and 130-keV monoE with O-MAR