Fig. 3 | European Radiology Experimental

Fig. 3

From: Comparison of gadolinium-based contrast agents for MR cholangiography in saline, blood and bile: a phantom study

Fig. 3

Signal intensities of gadoterate, gadobenate, and gadoxetate in saline and biological fluids on three-dimensional multiecho fast field-echo (3D mFFE) and multiecho gradient- and spin-echo (mGraSE) sequences. Signal intensities of gadoterate, gadobenate, and gadoxetate at different concentrations in saline (a), blood (b), and bile (c) on 3D-mFFE sequence. Signal intensities of gadoterate, gadobenate, and gadoxetate at different concentrations in saline (d), blood (e), and bile (f) on mGraSE sequence. * = significantly higher maximum signal intensity of the contrast agent than both other contrast agents; +  = significantly higher maximum signal intensity than the contrast agent with the lowest maximum signal intensity. * or +  = p < 0.050, ** or +  +  = p < 0.010; *** or +  +  +  = p < 0.001