Skip to main content

Table 1 Technical parameters for the main sequences used for the acquisition of cardiac magnetic resonance examinations in the study population

From: The predictive role of right ventricular late gadolinium enhancement in patients with tetralogy of Fallot undergoing pulmonary valve replacement

 

Cine

LGE

Sequence

Steady-state-free precession

Inversion recovery turbo FLASH

Time of echo (ms)

1.7

3.3

Time of repetition (ms)

3.0

3.5

Flip angle (°)

60–80

25

Slice thickness (mm)

8

8

Inversion time (ms)

-

280

Number of excitations

1

1

FoV read (mm)

350

400

FoV phase (%)

81.3

68.8

Phase oversampling (%)

54

50

PAT mode

GRAPPA

GRAPPA

  1. FoV Field of view, LGE Late gadolinium enhancement, PAT Parallel acquisition techniques