Table 2 Technical parameters of the diffusion-weighted imaging sequence

From: Simplified intravoxel incoherent motion DWI for differentiating malignant from benign breast lesions

Name

Value

FOV (RL × AP)/orientation

400 × 300 mm/transversal

Slice number/thickness/gap

29/4.0 mm/−1.0 mm

Matrix/pixel size

132 × 101/3.0 × 3.0 mm

Echo time

60 ms

Repetition time

2116 ms

EPI factor/half-Fourier factor/SENSE factor

55/0.6/2

Diffusion gradients

Three orthogonal directions

Duration/distance

22.6/31.9 ms

b values (number of excitations)

0, 50, 250 s/mm2 (3), 800 s/mm2 (6)

Fat suppression method

STIR (inversion time = 180 ms)

Water-fat shift/bandwidth

7.1 pixel/30.4 Hz

Bandwidth in EPI frequency direction

2203.5 Hz

Acquisition time

2:53 min:s

  1. AP Anterior-posterior, EPI Echo-planar imaging, FOV Field of view, RL Right-left, SENSE Parallel imaging with sensitivity encoding, STIR Short-time inversion recovery